For HRP series condensate pump
Introduction
Hitech condensate pumps are designed to automatically remove the condensate
from an air-conditioner, evaporator coil and/or an oil or gas condensing warm
air boiler. This pump is made from a tough ABS plastic body so it will resist
corrosion and impact.
- Feature
- Light and compact size
- Easy installation
- Stainless steel shaft
- Check valve to prevent back flow of liquid into unit
- Optional safety switch
- ABS construction
- Silent running motor
- Four drain holes
- Thermal overload protection
- Strong motor
- Specification
|
Model
|
Dimensions
(HxWxL, mm)
|
Volts
|
AMP
|
Watt
|
liter/h
|
Check
valve
|
Safety
switch
|
Height
|
Tnak
capacity
(l)
|
|
1M
|
2M
|
4M
|
6M
|
8M
|
12M
|
|
HRP-2M
|
95x65x166
|
220
|
0.3
|
35
|
120
|
25
|
|
|
|
|
installed
|
|
2M
|
0.1
|
|
HRP-4M-I
|
95x87x185
|
0.5
|
65
|
270
|
250
|
170
|
|
|
|
|
4M
|
1
|
|
HRP-4M
|
185x135x256
|
0.5
|
65
|
270
|
250
|
170
|
|
|
|
option
|
4M
|
2
|
|
HRP-6M
|
0.8
|
100
|
390
|
335
|
270
|
180
|
|
|
6M
|
|
HRP-8M
|
1.2
|
150
|
|
460
|
405
|
270
|
180
|
|
8M
|
|
HRP-12M
|
243x165x320
|
0.5
|
180
|
|
|
620
|
580
|
500
|
120
|
12M
|
3.4
|
|
HRP-15M
|
1.0
|
260
|
|
|
|
700
|
650
|
470
|
15M
|
3.4
|
Installation
- Carefully unpack the unit and check for damage and make sure all required
part are included.
- Choose a mounting location near the air-conditioner or boiler.
The pump must be mounted level. And the inlet must be below the lowest drain.
- Connection pipe:
- Run flexible tubing or pipe on the condensate drain on the evaporator
pan or /and drain from boiler to inlet hole on the pump.
- Connect the discharge line by hand-tighten the cap nut of the check
valve in a clockwise direction.
- For the best result, the drain should be below or approx. level with
the bottom of the pump tank.
- Testing
With the unit plugged in and the discharge line in place, pour water into
the pump reservoir until the unit activates to verify the unit works properly.
Maintenance
Warning! Before attempting any maintenance on the unit, disconnect the power
cord from the power supply to reduce the risk of electrical shock.
- Cleaning the check valve and verify its operating
- After unscrewing the cap nut remove the discharge line from the check valve
- Use a wrench to remove the check valve from the drive unit.
- Visually check the valve for obstructions. If damaged, replace.
- To re-install the check valve, hands tighten it to the drive unit.
Then, tighten 1/2-turn further with a wrench. Be careful not to over-tighten
as this may distort the O-ring seal under the check valve.
Replacement items
The discharge nipple with integrated check valve is available for replacement.
It can be used for both pump models.
Troubleshooting
If the pump does not function properly, refer to the following :
- Unit does not run:
- Check the power supply
- Check the appliance to see if condensation is actually being generated
- Check to make sure the pump float mechanism moves freely and clicks
the activation switch when moved up and down.
- Check the drain line(s) into the pump for obstructions. Note: If these
lines are clogged and remain clogged, the appliance may eventually be
damaged.
- Pump makes loud noise when running :
- Check the tank for debris and clean if necessary. Refer to the maintenance
section for cleaning instructions.
- Unit runs but does not pump liquid out :
- Check the floats to be sure that they are not stuck in the up position.
- Check the height of the discharge tubing to be sure it does not exceed
the allowed head (see specifications)
- Check the discharge tube for obstructions and clear if needed.
- Check the check valve for obstructions. Refer to the maintenance section
for cleaning instructions.
- Liquid drains back into pump from discharge line :
- Check valve may have debris in it. Refer to the maintenance section
for cleaning instructions
- If the discharge line is plumbed so the highest point is less than
1 m above the pump, the check valve may allow liquid to drain out of the
line. This is normal and will not damage the pump.
- Liquid leaks from around the check valve
- Check the proper fit of the cap nut that holds the discharge tube in
place.
- If the check valve is too tight or too loose it may leak around the
O-ring. Check that the valve is hand tight, and then tighten an addition
1/2 turn with a wrench.
- If the O-ring under the check valve is damaged, replace with a new
one or purchase a replacement check valve, which includes an O-ring.
Warranty
1 year. This warranty covers all parts with material or manufacturing faults.
The buyer's only remedy is the replacement or repair of the defective parts.
In no case can labour costs and any consequential damage be cited as a basis
for a complaint. Any returned units must be complete and must be accompanied
by a written list of the defects ascertained.
We are unable to accept any liability in case of nonconforming installation
or noncompliance with the specifications or maintenance recommendations.
Caution
- Don't use our pumps in the alcohol, gasoline & combustible material.
- Don't use in hot water over 60°C.
- Don't treat our pumps with wet hand.
- Must not twist the hose.
- Avoid children's approch
- Use the pump with safety switch to prevent your property loss.
*note : We have Battery Powered safety Alarm(Water L.E.D
Alarm) separately.